600V 10000 Watt 3 Phase Solar Hybrid Inverter DC To AC In Parallel

Felicity Solar IVGM100600 is a multifunctional inverter that combines the functions of inverter, solar charger and battery charger, DC to AC output, 3 phase hybrid inverter, 600V 10KW high voltage inverter for hybrid solar system, with lithium Batteries/gel batteries store electrical energy.
  • Item NO.:IVGM100600-HT
  • Lead Time:2-15days
  • Product Origin:China
  • Shipping Port:Guangzhou
  • Payment:TT/PayPal/Western Union
  • Color:White/Black/Orange

PRODUCT DETAIL

The main function of the photovoltaic inverter is to convert the direct current generated by the solar panel into the alternating current used by home appliances. It is divided into two types: grid-connected inverter and off-grid inverter. high power and low cost.

The biggest difference of the grid-connected inverter is that it does not do any battery storage (of course, it can also be used with energy storage batteries for high-priced electricity), and the direct current generated from the solar panel is directly converted into alternating current through inverter and directly connected to the public power grid. , but there are certain thresholds, that is, it must comply with the relevant regulations and policies of the local power grid, otherwise the grid connection cannot be provided. And we have Grid regulation: VDE-AR-N 4105; G99/1; EN50549-1; CEI 0-21; AS 4777.2; NRS 097-2-1; Safety regulation: IEC 62109-1/2; IEC62040-1.

Product Advantages:

· Support Wi-Fi for mobile monitoring.
· Max. charging/discharging current of 25A.
· AC couple to retrofit existing solar system.
· Support storing energy from diesel generator.
· Power supply can be switched automatically and switching time within 20ms.
· Long warranty period:10 years.
· Convenient RS232/RS485 Communication.
· IP65 Protection level.
· Support 3 Phase imbalance.

Data Sheet

 Model IVGM100600
 Battery Input Data
 Battery Voltage Range 180V~ 580V
 Max. charging and discharging current 25A
 Max. charging and discharging power 10000W
 Battery type Li-Ion Lead-acid
 DC Input DataPV side
 Max. recommended PV power 13000W
 Max. PV voltage 900V
 Start voltage 160V
 PV voltage range 160V~900V
 MPPT voltage range 200V~850V
 MPPT Voltage Range for Full Load 450V~850V
 Nominal voltage 720V
 Max. input current 15A / 15A
 Max. shorted curent 18A18A
 Number of MPP trackers/ strings per MPP tracker 2/1
 Grid Data
 Nominal Input Voltage 230Vac/400Vac
 Input Voltage Range 184~ 264. 5 Vac *
 Nominal grid frequency 50/60Hz *
 Max. input current 30A
 Max. Charge Current 25A
 Max. AC output power 10000W
 AC Output Rated Current 20A
 Max. output current 18A
 Max. Continuous AC Pass through 30A
 Power factor 0.99
 Displacement power factor 0.8leading ···0.8lagging
 THDI <3%
 AC Output Data(Back Up)
 Rated output power 10000VA10000W
 Max. Output current 30A
 Rated AC output voltage 230Vac
 Rated AC output frequency 50 60Hz
 Efficiency
 Max. efficiency 97.60%
 Euro efficiency 97.00%
 MPPT efficiency 99.90%
 General Data
 Operating temperature range – 25°C 60°C, 45°C Derating
 Protection degree IP65
 Relative humidity 100%
 Cooling concept Nature
 Altitude 2000m
 Communication RS232RS485
 BMS Communication CANRS485
 Monitor module WiFi GPRS
 Display LCD+LED
 Installation Style Wall-mounted
 Warranty 10 years
 Grid Regulation VDE-AR-N 4105; G99/1; EN50549-1; CEI 0-21; AS 4777.2; NRS 097-2-1;
 Safety Regulation IEC 62109-1/2; IEC62040-1.
 EMC EN6 10 00-6-1 EN61000-6-3
 Net Weight(KG) 36.2KG
 Gross Weight(KG) 41.5KG
 Product Dimension(MM) 533 *431 213
 Package Dimension(MM) 635 *533 *321

 

Product Details

RFQ

 

1.How to choose suitable inverter?

If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.

2.How do I choose the size of the inverter?

Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.